Skip to Store Area:

Welcome to JRRshop.com!

カートの中には何もありません。


You're currently on:

+ Click images to enlarge

Hornberg HB1 MIDI Breath Station

この商品の最初のレビューを書く

Manufacturer

Availability: Usually ships within 2-7 days.

$849.00
Add Items to Cart

クイックビュー

The Breath Controller for sensitive LIVE and STUDIO performance.


The hb1 MIDI Breath Station enables you to regulate any electronic instrument or peripheral device with MIDI or USB-port.

The hb1 MIDI Breath Station enables you to regulate any electronic instrument or peripheral device with MIDI or USB-port. The special wooden mouth piece, a precision sensor and the combination of a MIDI-merger, an integrated MIDI-interface and the innovative parameters create the premise for a high precision and highly sensitive performance of your ideas, in studio or live. Ten of the twelve parameters allow an adaption of various details and impulses in your music. For instance, the adjustable “Release” allows breathing in without a gap in the sound.The “Dynamic Attack” parameter allows for sensitive sound control, even in the finest pianissimo. In dual mode you can control two independent MIDI CCs even simultaneously. Realtime data reduction, Inversion and Limitation of the signal and, of course, Drive and Offset are all a part of the setting options. Each parameter can be saved in 25 presets. Additionally, the breath-data is displayed constantly on the Breath-Value Display. The hb1 approach is innovative and progresses far beyond the possibilities of a common breath controller. Through the integration of standard MIDI and USB-ports, the hb1 functions with or without a computer. The hb1 is hand-crafted in Germany with great attention to detail as well as with a focus on the aspect of sustainability.

 

 

The hb1 is composed of a controller unit and an extremely accurate pressure sensor unit which is connected to the mouthpiece by a silicon hose and to the controller unit by a sensor cable. Two mouthpieces are supplied in different sizes so that the most comfortable can be chosen for use.

The mouthpiece, made of precious wood from the wild service tree, is mounted onto a stainless steel tube in which the sliding adjustable air intake valve can be adjusted as needed. The pressure sensor unit may be worn hung by a leather cord around the neck with the mouthpiece between the lips. The hb1 includes a Neck Set which enables the mouthpiece to be set in a fixed position in front of the mouth. This is particularly helpful for live performances. The hb1 Neck Set is made from a flexible but robust metal tube which can be easily shaped and adapted for the musician's comfort and musical needs.

  • mouthpieces

    Two mouthpieces

  • hb1 neck set3

    hb1 Neck Set

  • hb1 neck set1

    hb1 Neck Set - front view

  • hb1 neck set2

    hb1 Neck Set - side view

Connection of mouthpiece and pressure sensor unit

connection of mouthpiece and pressure sensor unit

 

Any keyboard (or a MIDI guitar, etc) can be connected by its MIDI OUT to hb1 over its MIDI IN. This means that the merged Midi data of the keyboard and the hb1 data are accessible on the MIDI OUT and USB OUT. The MIDI OUT of the hb1 can also be directly connected over the MIDI IN to a synthesizer or over the USB port of a computer. The hb1 provides an additional MIDI OUT 2 through its integrated USB MIDI-interface.

See the following connection diagram:

hb1 use

hb1 Parameters

  • presets Presets

    Range: 1 - 25

    There are 25 presets that can be individually set according to your requirements.
  • drive Drive

    Range: -10 - +10

    Drive controls the sensitivity of the pressure sensor, i.e. you can adjust the hb1 to your breathing pressure. The larger the value, the more sensitively the hb1 will react to your breathing. If Drive 0 the pressure sensor unit will be switched off.

    Invert-Function:

    For a negative drive value, the output signal and the values of all parameters are inverted (except Pr, rd, CC and Ch). In principle, exhaling will turn into inhaling; in other words, exhaling decreases the output value while inhaling increases the output.
  • offset Offset

    Range: 0 - 126

    The base value starting point is set here prior to breathing into the mouthpiece. However, it is possible to fall below this value by breathing in.
  • attack Attack

    Range: 0 - 40

    Attack determines the speed at which output data follows the pressure curve when pressure is increased. With breath controllers, it is often very difficult (particularly with brass instruments) to achieve a sensitive, controlled “crescendo”. The crescendo rises too quickly.
    To achieve smooth transitions, hb1 has been equipped with „dynamic“ attack parameter which is dependent on the drive parameter.
    The combination of Drive, Attack and Release form the basis for a sensitive musical performance.
  • boost attack Boost Attack

    Range: 0 - 5

    The Boost Attack is achieved by blowing especially strongly which cancels the effect of the Attack-Parameter. Consequently, the end value can be reached immediately - even with a high Attack value.
  • release Release

    Range: 0 - 40

    Release regulates the decay time. Slowly decreasing pressure (decrescendo) along with breathing in seamlessly are particularly challenging technical functions for breath controllers. The Release parameter was developed to address this issue. Thanks to this parameter, it is no longer necessary to blow along with the decaying sound (release sample). Furthermore, you can use release as an effect parameter, e.g. as “auto-fade-out”.
  • boost release Boost Release

    Range: 0 - 5

    The Boost Release is achieved by very strongly inhaling the air so as to cancel the effect of the Release-Parameter. Consequently, the null value can be reached immediately - even with a high Release Value. 
  • limit Limit

    Range: 1 - 127

    Using the Limit function, you are able to set a maximum value (as the name suggests) that will not be exceeded.
  • data reduction Data Reduction

    Range: 0 - 20

    The hb1 works generally at a maximum resolution (1ms). However, it is sometimes useful to reduce data (e.g. overloaded MIDI bus).
    Using the intelligent „reduction algorithm“ of the hb1 you can reach the upper limit without risk of losing important information and occurrence of artefacts.
  • continuous controller Continuous Controller

    Range: 0 - 127

    All MIDI Continuous Controllers are supported.
  • midi channel MIDI Channel

    Range: 1 - 16

    Use to set the MIDI channel for sending controller data.
  • combined preset Combined Preset

    Range: 1 - 25

    With the parameter CP you can activate the dual mode. Enter the number of preset that determines the parameters of the second channel. Then work simultaneously with two presets, as if you were using two parallel hb1.
  • Items included

    • Controller unit
    • Pressure sensor unit
    • Two mouthpieces, made of precious wood of the wild service tree
    • One stainless steel tube with an adjustable air intake valve
    • hb1 Neck Set
    • Silicone hose
    • 2 m sensor cable (4-pole)
    • 1.8 m USB cable
    • 5V USB power supply unit
    • Cleaning swab for the mouthpiece
    • Wool felt carrying case
  • Minimum System Requirements for use with computer

    • 1 x USB 2.0 Port
    • Works with any standard operating system
    • Recommendation: use current operating systems
    • No driver installation necessary (Plug&Play)
  • Technical Data

    • Manufacturer: Hornberg Research GbR
    • Model: hb1
    • Description: MIDI Breath Station
    • Electrical supply: U=4,75V - 5,25 V, I < 100mA
    • via USB interface or USB power supply (included)
    • connection via USB Model B socket
    • internal resolution: 1ms
    • Connections:
    • 1 x DIN-MIDI IN 31250 bit/s, 5 mA
    • 2 x DIN-MIDI OUT 31250 bit/s
    • USB 2.0
    • Connection for the pressure sensor unit
Variant1